High voltage DC contactors, for operation at voltage levels up to at least about 300 volts, find their increasing markets in applications such as electrical vehicles and aircrafts in which size and weight of cables are of extreme importance. The copper bridge-type contact, cooperated with magnetic field provided by permanent magnets and sealed in an arc chamber filled with high pressure gases, is a mainly used structure to interrupt the DC arc rapidly. Arc characteristic in different gases at different pressure varies greatly. This paper is focused on the arc characteristics of the bridge-type contact system when magnetic field is applied with nitrogen and gas at different pressure. The pressure of the gases varies from 1 atm to 2.5 atm. Arc characteristics, such as arc durations at different stages and arc motions in those gases are comparatively studied. The results are instructive for choosing the suitable arcing atmosphere in a DC bridge-type arc chamber of a contactor.
Xue ZHOU
Harbin Institute of Technology
Mo CHEN
Harbin Institute of Technology
Xinglei CUI
Harbin Institute of Technology
Guofu ZHAI
Harbin Institute of Technology
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Xue ZHOU, Mo CHEN, Xinglei CUI, Guofu ZHAI, "Study on Arc Characteristics of a DC Bridge-type Contact in Air and Nitrogen at Different Pressure" in IEICE TRANSACTIONS on Electronics,
vol. E97-C, no. 9, pp. 850-857, September 2014, doi: 10.1587/transele.E97.C.850.
Abstract: High voltage DC contactors, for operation at voltage levels up to at least about 300 volts, find their increasing markets in applications such as electrical vehicles and aircrafts in which size and weight of cables are of extreme importance. The copper bridge-type contact, cooperated with magnetic field provided by permanent magnets and sealed in an arc chamber filled with high pressure gases, is a mainly used structure to interrupt the DC arc rapidly. Arc characteristic in different gases at different pressure varies greatly. This paper is focused on the arc characteristics of the bridge-type contact system when magnetic field is applied with nitrogen and gas at different pressure. The pressure of the gases varies from 1 atm to 2.5 atm. Arc characteristics, such as arc durations at different stages and arc motions in those gases are comparatively studied. The results are instructive for choosing the suitable arcing atmosphere in a DC bridge-type arc chamber of a contactor.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/transele.E97.C.850/_p
Copy
@ARTICLE{e97-c_9_850,
author={Xue ZHOU, Mo CHEN, Xinglei CUI, Guofu ZHAI, },
journal={IEICE TRANSACTIONS on Electronics},
title={Study on Arc Characteristics of a DC Bridge-type Contact in Air and Nitrogen at Different Pressure},
year={2014},
volume={E97-C},
number={9},
pages={850-857},
abstract={High voltage DC contactors, for operation at voltage levels up to at least about 300 volts, find their increasing markets in applications such as electrical vehicles and aircrafts in which size and weight of cables are of extreme importance. The copper bridge-type contact, cooperated with magnetic field provided by permanent magnets and sealed in an arc chamber filled with high pressure gases, is a mainly used structure to interrupt the DC arc rapidly. Arc characteristic in different gases at different pressure varies greatly. This paper is focused on the arc characteristics of the bridge-type contact system when magnetic field is applied with nitrogen and gas at different pressure. The pressure of the gases varies from 1 atm to 2.5 atm. Arc characteristics, such as arc durations at different stages and arc motions in those gases are comparatively studied. The results are instructive for choosing the suitable arcing atmosphere in a DC bridge-type arc chamber of a contactor.},
keywords={},
doi={10.1587/transele.E97.C.850},
ISSN={1745-1353},
month={September},}
Copy
TY - JOUR
TI - Study on Arc Characteristics of a DC Bridge-type Contact in Air and Nitrogen at Different Pressure
T2 - IEICE TRANSACTIONS on Electronics
SP - 850
EP - 857
AU - Xue ZHOU
AU - Mo CHEN
AU - Xinglei CUI
AU - Guofu ZHAI
PY - 2014
DO - 10.1587/transele.E97.C.850
JO - IEICE TRANSACTIONS on Electronics
SN - 1745-1353
VL - E97-C
IS - 9
JA - IEICE TRANSACTIONS on Electronics
Y1 - September 2014
AB - High voltage DC contactors, for operation at voltage levels up to at least about 300 volts, find their increasing markets in applications such as electrical vehicles and aircrafts in which size and weight of cables are of extreme importance. The copper bridge-type contact, cooperated with magnetic field provided by permanent magnets and sealed in an arc chamber filled with high pressure gases, is a mainly used structure to interrupt the DC arc rapidly. Arc characteristic in different gases at different pressure varies greatly. This paper is focused on the arc characteristics of the bridge-type contact system when magnetic field is applied with nitrogen and gas at different pressure. The pressure of the gases varies from 1 atm to 2.5 atm. Arc characteristics, such as arc durations at different stages and arc motions in those gases are comparatively studied. The results are instructive for choosing the suitable arcing atmosphere in a DC bridge-type arc chamber of a contactor.
ER -