This paper presents an automatic adjustment of the transfer function of phase locked loop (PLL). The time constants and the gain factor of the transfer function are adjusted without opening the loop of PLL. The time constant adjustment is performed using a replica of the 1st order RC low pass filter and the gain factor is adjusted by detecting the open loop gain at the unity gain frequency. These adjustments are automatically carried out using a digitally controlled capacitance array and a digitally controlled charge pump. The proposed calibration can reduce the bandwidth error of
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Masahiro YOSHIOKA, Nobuo FUJII, "Automatic Adjustment of Phase Locked Loop Transfer Function" in IEICE TRANSACTIONS on Fundamentals,
vol. E91-A, no. 2, pp. 483-490, February 2008, doi: 10.1093/ietfec/e91-a.2.483.
Abstract: This paper presents an automatic adjustment of the transfer function of phase locked loop (PLL). The time constants and the gain factor of the transfer function are adjusted without opening the loop of PLL. The time constant adjustment is performed using a replica of the 1st order RC low pass filter and the gain factor is adjusted by detecting the open loop gain at the unity gain frequency. These adjustments are automatically carried out using a digitally controlled capacitance array and a digitally controlled charge pump. The proposed calibration can reduce the bandwidth error of
URL: https://global.ieice.org/en_transactions/fundamentals/10.1093/ietfec/e91-a.2.483/_p
Copy
@ARTICLE{e91-a_2_483,
author={Masahiro YOSHIOKA, Nobuo FUJII, },
journal={IEICE TRANSACTIONS on Fundamentals},
title={Automatic Adjustment of Phase Locked Loop Transfer Function},
year={2008},
volume={E91-A},
number={2},
pages={483-490},
abstract={This paper presents an automatic adjustment of the transfer function of phase locked loop (PLL). The time constants and the gain factor of the transfer function are adjusted without opening the loop of PLL. The time constant adjustment is performed using a replica of the 1st order RC low pass filter and the gain factor is adjusted by detecting the open loop gain at the unity gain frequency. These adjustments are automatically carried out using a digitally controlled capacitance array and a digitally controlled charge pump. The proposed calibration can reduce the bandwidth error of
keywords={},
doi={10.1093/ietfec/e91-a.2.483},
ISSN={1745-1337},
month={February},}
Copy
TY - JOUR
TI - Automatic Adjustment of Phase Locked Loop Transfer Function
T2 - IEICE TRANSACTIONS on Fundamentals
SP - 483
EP - 490
AU - Masahiro YOSHIOKA
AU - Nobuo FUJII
PY - 2008
DO - 10.1093/ietfec/e91-a.2.483
JO - IEICE TRANSACTIONS on Fundamentals
SN - 1745-1337
VL - E91-A
IS - 2
JA - IEICE TRANSACTIONS on Fundamentals
Y1 - February 2008
AB - This paper presents an automatic adjustment of the transfer function of phase locked loop (PLL). The time constants and the gain factor of the transfer function are adjusted without opening the loop of PLL. The time constant adjustment is performed using a replica of the 1st order RC low pass filter and the gain factor is adjusted by detecting the open loop gain at the unity gain frequency. These adjustments are automatically carried out using a digitally controlled capacitance array and a digitally controlled charge pump. The proposed calibration can reduce the bandwidth error of
ER -