The search functionality is under construction.

IEICE TRANSACTIONS on Fundamentals

Automatic Adjustment of Phase Locked Loop Transfer Function

Masahiro YOSHIOKA, Nobuo FUJII

  • Full Text Views

    0

  • Cite this

Summary :

This paper presents an automatic adjustment of the transfer function of phase locked loop (PLL). The time constants and the gain factor of the transfer function are adjusted without opening the loop of PLL. The time constant adjustment is performed using a replica of the 1st order RC low pass filter and the gain factor is adjusted by detecting the open loop gain at the unity gain frequency. These adjustments are automatically carried out using a digitally controlled capacitance array and a digitally controlled charge pump. The proposed calibration can reduce the bandwidth error of 30% to 5% and the gain error of 7 dB to 1 dB.

Publication
IEICE TRANSACTIONS on Fundamentals Vol.E91-A No.2 pp.483-490
Publication Date
2008/02/01
Publicized
Online ISSN
1745-1337
DOI
10.1093/ietfec/e91-a.2.483
Type of Manuscript
Special Section PAPER (Special Section on Analog Circuit Techniques and Related Topics)
Category

Authors

Keyword