A novel sensor system of denture base type was developed for simultaneous monitoring of salivary pH and tissue temperature in the oral cavity. Fundamental components of the monitoring system, sensor devices and sensor configuration are showed in this paper. The sensor units consist of IrO2 electrode and thermistor circuit implanted in the denture base that is tightly fixed in the oral cavity. The signals are transmitted by PFM-FM telemeter system that can be used for health care of the aged people without restraint of their daily behavior while at work, sleeping and even at exercise. Some of results concerning the basic characteristics of the sensor system and continuously monitored physiological data were obtained from the preliminary experiments. Availability of the whole system and monitoring method was discussed.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Haruyuki MINAMITANI, Yoichiro SUZUKI, Atsuhiko IIJIMA, Tomokazu NAGAO, "A Denture Base Type of Sensor System for Simultaneous Monitoring of Hydrogen Ion Concentration pH and Tissue Temperature in the Oral Cavity" in IEICE TRANSACTIONS on Information,
vol. E85-D, no. 1, pp. 22-29, January 2002, doi: .
Abstract: A novel sensor system of denture base type was developed for simultaneous monitoring of salivary pH and tissue temperature in the oral cavity. Fundamental components of the monitoring system, sensor devices and sensor configuration are showed in this paper. The sensor units consist of IrO2 electrode and thermistor circuit implanted in the denture base that is tightly fixed in the oral cavity. The signals are transmitted by PFM-FM telemeter system that can be used for health care of the aged people without restraint of their daily behavior while at work, sleeping and even at exercise. Some of results concerning the basic characteristics of the sensor system and continuously monitored physiological data were obtained from the preliminary experiments. Availability of the whole system and monitoring method was discussed.
URL: https://global.ieice.org/en_transactions/information/10.1587/e85-d_1_22/_p
Copy
@ARTICLE{e85-d_1_22,
author={Haruyuki MINAMITANI, Yoichiro SUZUKI, Atsuhiko IIJIMA, Tomokazu NAGAO, },
journal={IEICE TRANSACTIONS on Information},
title={A Denture Base Type of Sensor System for Simultaneous Monitoring of Hydrogen Ion Concentration pH and Tissue Temperature in the Oral Cavity},
year={2002},
volume={E85-D},
number={1},
pages={22-29},
abstract={A novel sensor system of denture base type was developed for simultaneous monitoring of salivary pH and tissue temperature in the oral cavity. Fundamental components of the monitoring system, sensor devices and sensor configuration are showed in this paper. The sensor units consist of IrO2 electrode and thermistor circuit implanted in the denture base that is tightly fixed in the oral cavity. The signals are transmitted by PFM-FM telemeter system that can be used for health care of the aged people without restraint of their daily behavior while at work, sleeping and even at exercise. Some of results concerning the basic characteristics of the sensor system and continuously monitored physiological data were obtained from the preliminary experiments. Availability of the whole system and monitoring method was discussed.},
keywords={},
doi={},
ISSN={},
month={January},}
Copy
TY - JOUR
TI - A Denture Base Type of Sensor System for Simultaneous Monitoring of Hydrogen Ion Concentration pH and Tissue Temperature in the Oral Cavity
T2 - IEICE TRANSACTIONS on Information
SP - 22
EP - 29
AU - Haruyuki MINAMITANI
AU - Yoichiro SUZUKI
AU - Atsuhiko IIJIMA
AU - Tomokazu NAGAO
PY - 2002
DO -
JO - IEICE TRANSACTIONS on Information
SN -
VL - E85-D
IS - 1
JA - IEICE TRANSACTIONS on Information
Y1 - January 2002
AB - A novel sensor system of denture base type was developed for simultaneous monitoring of salivary pH and tissue temperature in the oral cavity. Fundamental components of the monitoring system, sensor devices and sensor configuration are showed in this paper. The sensor units consist of IrO2 electrode and thermistor circuit implanted in the denture base that is tightly fixed in the oral cavity. The signals are transmitted by PFM-FM telemeter system that can be used for health care of the aged people without restraint of their daily behavior while at work, sleeping and even at exercise. Some of results concerning the basic characteristics of the sensor system and continuously monitored physiological data were obtained from the preliminary experiments. Availability of the whole system and monitoring method was discussed.
ER -