This paper considers a 2-dissimilar unit warm standby system. The failure rates are constant but the repair rates need not be constant. We shall say that a major breakdown occurs in the system when both unit fail. The system fails if one unit under repair is not repaired within a fixed time measured from the instant at which major breakdown occurs, or if the number of major breakdowns during the mission period exceeds a fixed number. As a special case, this number is allowed to be
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Masanori KODAMA, "Mission Reliability for a 2-Dissimilar Unit Warm Standby System with Allowed Down Time and Allowed Number of Failures" in IEICE TRANSACTIONS on transactions,
vol. E59-E, no. 12, pp. 1-7, December 1976, doi: .
Abstract: This paper considers a 2-dissimilar unit warm standby system. The failure rates are constant but the repair rates need not be constant. We shall say that a major breakdown occurs in the system when both unit fail. The system fails if one unit under repair is not repaired within a fixed time measured from the instant at which major breakdown occurs, or if the number of major breakdowns during the mission period exceeds a fixed number. As a special case, this number is allowed to be
URL: https://global.ieice.org/en_transactions/transactions/10.1587/e59-e_12_1/_p
Copy
@ARTICLE{e59-e_12_1,
author={Masanori KODAMA, },
journal={IEICE TRANSACTIONS on transactions},
title={Mission Reliability for a 2-Dissimilar Unit Warm Standby System with Allowed Down Time and Allowed Number of Failures},
year={1976},
volume={E59-E},
number={12},
pages={1-7},
abstract={This paper considers a 2-dissimilar unit warm standby system. The failure rates are constant but the repair rates need not be constant. We shall say that a major breakdown occurs in the system when both unit fail. The system fails if one unit under repair is not repaired within a fixed time measured from the instant at which major breakdown occurs, or if the number of major breakdowns during the mission period exceeds a fixed number. As a special case, this number is allowed to be
keywords={},
doi={},
ISSN={},
month={December},}
Copy
TY - JOUR
TI - Mission Reliability for a 2-Dissimilar Unit Warm Standby System with Allowed Down Time and Allowed Number of Failures
T2 - IEICE TRANSACTIONS on transactions
SP - 1
EP - 7
AU - Masanori KODAMA
PY - 1976
DO -
JO - IEICE TRANSACTIONS on transactions
SN -
VL - E59-E
IS - 12
JA - IEICE TRANSACTIONS on transactions
Y1 - December 1976
AB - This paper considers a 2-dissimilar unit warm standby system. The failure rates are constant but the repair rates need not be constant. We shall say that a major breakdown occurs in the system when both unit fail. The system fails if one unit under repair is not repaired within a fixed time measured from the instant at which major breakdown occurs, or if the number of major breakdowns during the mission period exceeds a fixed number. As a special case, this number is allowed to be
ER -