A novel double-image Green's function approach is proposed to compute the frequency- dependent capacitance and conductance for the general CMOS oriented transmission lines with one protective layer. The ε-algorithm of Pade approximation is adopted to reduce the time for establishing coefficient matrix in this letter. The parameters gained from this new approach are shown to be in good agreement with the data obtained by the full-wave method and the total charge Green's function method.
The copyright of the original papers published on this site belongs to IEICE. Unauthorized use of the original or translated papers is prohibited. See IEICE Provisions on Copyright for details.
Copy
Wenliang DAI, Zhengfan LI, Junfa MAO, "Double-Image Green's Function Method for CMOS Process Oriented Transmission Lines" in IEICE TRANSACTIONS on Electronics,
vol. E86-C, no. 12, pp. 2504-2507, December 2003, doi: .
Abstract: A novel double-image Green's function approach is proposed to compute the frequency- dependent capacitance and conductance for the general CMOS oriented transmission lines with one protective layer. The ε-algorithm of Pade approximation is adopted to reduce the time for establishing coefficient matrix in this letter. The parameters gained from this new approach are shown to be in good agreement with the data obtained by the full-wave method and the total charge Green's function method.
URL: https://global.ieice.org/en_transactions/electronics/10.1587/e86-c_12_2504/_p
Copy
@ARTICLE{e86-c_12_2504,
author={Wenliang DAI, Zhengfan LI, Junfa MAO, },
journal={IEICE TRANSACTIONS on Electronics},
title={Double-Image Green's Function Method for CMOS Process Oriented Transmission Lines},
year={2003},
volume={E86-C},
number={12},
pages={2504-2507},
abstract={A novel double-image Green's function approach is proposed to compute the frequency- dependent capacitance and conductance for the general CMOS oriented transmission lines with one protective layer. The ε-algorithm of Pade approximation is adopted to reduce the time for establishing coefficient matrix in this letter. The parameters gained from this new approach are shown to be in good agreement with the data obtained by the full-wave method and the total charge Green's function method.},
keywords={},
doi={},
ISSN={},
month={December},}
Copy
TY - JOUR
TI - Double-Image Green's Function Method for CMOS Process Oriented Transmission Lines
T2 - IEICE TRANSACTIONS on Electronics
SP - 2504
EP - 2507
AU - Wenliang DAI
AU - Zhengfan LI
AU - Junfa MAO
PY - 2003
DO -
JO - IEICE TRANSACTIONS on Electronics
SN -
VL - E86-C
IS - 12
JA - IEICE TRANSACTIONS on Electronics
Y1 - December 2003
AB - A novel double-image Green's function approach is proposed to compute the frequency- dependent capacitance and conductance for the general CMOS oriented transmission lines with one protective layer. The ε-algorithm of Pade approximation is adopted to reduce the time for establishing coefficient matrix in this letter. The parameters gained from this new approach are shown to be in good agreement with the data obtained by the full-wave method and the total charge Green's function method.
ER -