The search functionality is under construction.

IEICE TRANSACTIONS on Electronics

High-Power Protection Switch Using Stub/Line Selectable Circuits

Masatake HANGAI, Kazuhiko NAKAHARA, Mamiko YAMAGUCHI, Morishige HIEDA

  • Full Text Views

    0

  • Cite this

Summary :

High-power protection switch utilizing a new stub/line selectable configuration is presented. By employing the proposed circuit topology, the insertion loss at receiving mode and the power handling capability at transmitting mode can be independently designed. Therefore, the proposed circuit is able to achieve low insertion loss at receiving mode while keeping high-power performance at transmitting mode. To verify this methodology, MMIC switch has been fabricated in Ka-band. The circuit has achieved the insertion loss of 2 dB, the isolation of 25 dB, and the power handling capability of 40 dBm at 5% bandwidth.

Publication
IEICE TRANSACTIONS on Electronics Vol.E94-C No.5 pp.814-819
Publication Date
2011/05/01
Publicized
Online ISSN
1745-1353
DOI
10.1587/transele.E94.C.814
Type of Manuscript
Special Section PAPER (Special Section on Fundamentals and Applications of Advanced Semiconductor Devices)