  • Feasibility Study of Numerical Calculation and Machine Learning Hybrid Approach for Renal Denervation Temperature Prediction

    Aditya RAKHMADI  Kazuyuki SAITO  

     
    PAPER-Electromagnetic Theory

      Pubricized:
    2023/05/22
      Vol:
    E106-C No:12
      Page(s):
    799-807

    Transcatheter renal denervation (RDN) is a novel treatment to reduce blood pressure in patients with resistant hypertension using an energy-based catheter, mostly radio frequency (RF) current, by eliminating renal sympathetic nerve. However, several inconsistent RDN treatments were reported, mainly due to RF current narrow heating area, and the inability to confirm a successful nerve ablation in a deep area. We proposed microwave energy as an alternative for creating a wider ablation area. However, confirming a successful ablation is still a problem. In this paper, we designed a prediction method for deep renal nerve ablation sites using hybrid numerical calculation-driven machine learning (ML) in combination with a microwave catheter. This work is a first-step investigation to check the hybrid ML prediction capability in a real-world situation. A catheter with a single-slot coaxial antenna at 2.45 GHz with a balloon catheter, combined with a thin thermometer probe on the balloon surface, is proposed. Lumen temperature measured by the probe is used as an ML input to predict the temperature rise at the ablation site. Heating experiments using 6 and 8 mm hole phantom with a 41.3 W excited power, and 8 mm with 36.4 W excited power, were done eight times each to check the feasibility and accuracy of the ML algorithm. In addition, the temperature on the ablation site is measured for reference. Prediction by ML algorithm agrees well with the reference, with a maximum difference of 6°C and 3°C in 6 and 8 mm (both power), respectively. Overall, the proposed ML algorithm is capable of predicting the ablation site temperature rise with high accuracy.

  • Specific Absorption Rate (SAR) Calculations in the Abdomen of the Human Body Caused by Smartphone at Various Tilt Angles: A Consideration of the 1950MHz Band

    Chiaki TAKASAKA  Kazuyuki SAITO  Masaharu TAKAHASHI  Tomoaki NAGAOKA  Kanako WAKE  

     
    PAPER-Electromagnetic Compatibility(EMC)

      Pubricized:
    2021/09/01
      Vol:
    E105-B No:3
      Page(s):
    295-301

    Various electromagnetic (EM) wave applications have become commonplace, and humans are frequently exposed to EM waves. Therefore, the effect of EM waves on the human body should be evaluated. In this study, we focused on the specific absorption rate (SAR) due to the EM waves emitted from smartphones, developed high-resolution numerical smartphone models, and studied the SAR variation by changing the position and tilt angle (the angle between the display of the smartphone model and horizontal plane) of the smartphone models vis-à-vis the human abdomen, assuming the use of the smartphone at various tilt angles in front of the abdomen. The calculations showed that the surface shape of the human model influenced the SAR variation.

  • Acoustic Design Support System of Compact Enclosure for Smartphone Using Deep Neural Network

    Kai NAKAMURA  Kenta IWAI  Yoshinobu KAJIKAWA  

     
    PAPER-Engineering Acoustics

      Vol:
    E102-A No:12
      Page(s):
    1932-1939

    In this paper, we propose an automatic design support system for compact acoustic devices such as microspeakers inside smartphones. The proposed design support system outputs the dimensions of compact acoustic devices with the desired acoustic characteristic. This system uses a deep neural network (DNN) to obtain the relationship between the frequency characteristic of the compact acoustic device and its dimensions. The training data are generated by the acoustic finite-difference time-domain (FDTD) method so that many training data can be easily obtained. We demonstrate the effectiveness of the proposed system through some comparisons between desired and designed frequency characteristics.

  • Dosimetry and Verification for 6-GHz Whole-Body Non-Constraint Exposure of Rats Using Reverberation Chamber

    Jingjing SHI  Jerdvisanop CHAKAROTHAI  Jianqing WANG  Kanako WAKE  Soichi WATANABE  Osamu FUJIWARA  

     
    PAPER

      Vol:
    E98-B No:7
      Page(s):
    1164-1172

    With the rapid increase of various uses of wireless communications in modern life, the high microwave and millimeter wave frequency bands are attracting much attention. However, the existing databases on above 6GHz radio-frequency (RF) electromagnetic (EM) field exposure of biological bodies are obviously insufficient. An in-vivo research project on local and whole-body exposure of rats to RF-EM fields above 6GHz was started in Japan in 2013. This study aims to perform a dosimetric design for the whole-body-average specific absorption rates (WBA-SARs) of unconstrained rats exposed to 6GHz RF-EM fields in a reverberation chamber (RC). The required input power into the RC is clarified using a two-step evaluation method in order to achieve a target exposure level in rats. The two-step method, which incorporates the finite-difference time-domain (FDTD) numerical solutions with electric field measurements in an RC exposure system, is used as an evaluation method to determine the whole-body exposure level in the rats. In order to verify the validity of the two-step method, we use S-parameter measurements inside the RC to experimentally derive the WBA-SARs with rat-equivalent phantoms and then compare those with the FDTD-calculated ones. It was shown that the difference between the two-step method and the S-parameter measurements is within 1.63dB, which reveals the validity and usefulness of the two-step technique.

  • Variability of Specific Absorption Rate of Human Body for Various Configurations of Tablet Computer in Vicinity of Abdomen

    Akihiro TATENO  Tomoaki NAGAOKA  Kazuyuki SAITO  Soichi WATANABE  Masaharu TAKAHASHI  Koichi ITO  

     
    PAPER

      Vol:
    E98-B No:7
      Page(s):
    1173-1181

    With the development and diverse use of wireless radio terminals, it is necessary to estimate the specific absorption rate (SAR) of the human body from such devices under various exposure situations. In particular, tablet computers may be used for a long time while placed near the abdomen. There has been insufficient evaluation of the SAR for the human body from tablet computers. Therefore, we investigated the SAR of various configurations of a commercial tablet computer using a numerical model with the anatomical structures of Japanese males and females, respectively. We find that the 10-g-averaged SAR of the tablet computer is strongly altered by the tablet's orientation, i.e., from -7.3dB to -22.6dB. When the tablet computer is moved parallel to the height direction, the relative standard deviations of the 10-g averaged SAR for the male and female models are within 40%. In addition, those for the different tilts of the computer are within 20%. The fluctuations of the 10-g-averaged SAR for the seated human models are within ±1.5dB in all cases.

  • Specific Absorption Rates and Temperature Elevations due to Wireless Radio Terminals in Proximity to a Fetus at Gestational Ages of 13, 18, and 26 Weeks

    Akihiro TATENO  Shimpei AKIMOTO  Tomoaki NAGAOKA  Kazuyuki SAITO  Soichi WATANABE  Masaharu TAKAHASHI  Koichi ITO  

     
    PAPER-Electromagnetic Compatibility(EMC)

      Vol:
    E97-B No:10
      Page(s):
    2175-2183

    As the electromagnetic (EM) environment is becoming increasingly diverse, it is essential to estimate specific absorption rates (SARs) and temperature elevations of pregnant females and their fetuses under various exposure situations. This study presents calculated SARs and temperature elevations in a fetus exposed to EM waves. The calculations involved numerical models for the anatomical structures of a pregnant Japanese woman at gestational stages of 13, 18, and 26 weeks; the EM source was a wireless portable terminal placed close to the abdomen of the pregnant female model. The results indicate that fetal SARs and temperature elevations are closely related to the position of the fetus relative to the EM source. We also found that, although the fetal SAR caused by a half-wavelength dipole antenna is sometimes comparable to or slightly more than the International Commission Non-Ionizing Radiation Protection guidelines, it is lower than the guideline level in more realistic situations, such as when a planar inverted-F antenna is used. Furthermore, temperature elevations were significantly below the threshold set to prevent the child from being born with developmental disabilities.

  • Quantification and Verification of Whole-Body-Average SARs in Small Animals Exposed to Electromagnetic Fields inside Reverberation Chamber

    Jingjing SHI  Jerdvisanop CHAKAROTHAI  Jianqing WANG  Kanako WAKE  Soichi WATANABE  Osamu FUJIWARA  

     
    PAPER-Electromagnetic Compatibility(EMC)

      Vol:
    E97-B No:10
      Page(s):
    2184-2191

    This paper aims to achieve a high-quality exposure level quantification of whole-body average-specific absorption rates (WBA-SARs) for small animals in a medium-size reverberation chamber (RC). A two-step method, which incorporates the finite-difference time-domain (FDTD) numerical solutions with electric field measurements in an RC-type exposure system, has been used as an evaluation method to determine the whole-body exposure level in small animals. However, there is little data that quantitatively demonstrate the validity and accuracy of this method in an RC up to now. In order to clarify the validity of the two-step method, we compare the physical quantities in terms of electric field strength and WBA-SARs by using a direct numerical assessment method known as the method of moments (MoM) with ten homogenous gel phantoms placed in an RC with 2GHz exposure. The comparison results show that the relative errors between the two-step method and the MoM approach are approximately below 10%, which reveals the validity and usefulness of the two-step technique. Finally, we perform a dosimetric analysis of the WBA-SARs for anatomical mouse models with the two-step method and determine the input power related to our developed RC-exposure system to achieve a target exposure level in small animals.

  • Magnetic Field Homogeneity of Birdcage Coil for 4T MRI System with No Lumped Circuit Elements

    Ryotaro SUGA  Kazuyuki SAITO  Masaharu TAKAHASHI  Koichi ITO  

     
    PAPER-Antennas and Propagation

      Vol:
    E97-B No:4
      Page(s):
    791-797

    In recent years, magnetic resonance imaging (MRI) systems that operate up to under 3T are being used in clinical practice in Japan. In order to achieve the requirements of higher image quality and shorter imaging times, devices that utilize high magnetic fields (> 3T) and high power electromagnetic (EM) wave pulses have been developed. The rise of the static magnetic field is proportional to the increase of the EM wave frequency which raises the issue of variation in capacitance used in the radio frequency (RF) coil for MRI system. In addition, increasing power causes problems of withstanding voltage and these approaches leads to generation of non-uniform magnetic field inside the RF coil. Therefore, we proposed a birdcage coil without the use of lumped circuit elements for MRI systems in previous study. However, it is difficult to fabricate this birdcage coil. Hence, simply-structured birdcage coil with no lumped circuit elements is desired. In this paper, we propose a simply-structured birdcage coil with no lumped circuit elements for a 4T MRI system. In addition, the authors investigated the input impedance and magnetic field distribution of the proposed coil by FDTD calculations and measurements. The results confirm that the proposed birdcage coil matches the performance of the conventional birdcage coil which includes several capacitors.

  • Development of RFID Antenna for Detection of Urination

    Hiromasa NAKAJIMA  Masaharu TAKAHASHI  Kazuyuki SAITO  Koichi ITO  

     
    PAPER-Antennas and Propagation

      Vol:
    E96-B No:9
      Page(s):
    2244-2250

    This paper introduces a radio frequency identification (RFID) tag for urination detection. The proposed tag is embedded into paper diapers in order to detect the patient's urination immediately. For this tag, we designed an RFID tag antenna at 950MHz, which matches the impedance of the associated integrated circuit (IC) chip. In addition, we calculate the antenna characteristics and measure the reflection coefficient (S11) and radiation pattern of the antenna. The results show that this system can be used to detect urination.