The search functionality is under construction.
The search functionality is under construction.

Keyword Search Result

[Keyword] magnet(669hit)

601-620hit(669hit)

  • Numerical Analysis of Dielectric Rod Waveguide with Corrugation of Nonintegral-Ratio Period Waves

    Hiroshi KUBO  Kimihisa FUKUSHIMA  Ikuo AWAI  

     
    PAPER

      Vol:
    E78-C No:10
      Page(s):
    1402-1408

    The dielectric rod waveguides with corrugation consisting of nonintegral-ratio period waves are investigated numerically. The leakage characteristics of HE11-type wave in the waveguide is analyzed by applying Yasuura's method. The complex propagation constants and the far field patterns are presented. The radiation pattern of a fabricated waveguide with corrugation agrees well with the calculated value. The dependence of radiation characteristics on the corrugation form is discussed. It is shown that the leakage directions and the intensity of leaky waves are controlled independently one another. The radiation pattern can be synthesized by choosing the geometric parameters of the corrugation properly.

  • Optical Constants of Magnetic Fluids and Their Application to Optical Switches

    Mitsunori SAITO  Makoto TAKAKUWA  Mitsunobu MIYAGI  

     
    PAPER-Opto-Electronics

      Vol:
    E78-C No:10
      Page(s):
    1465-1469

    The complex refractive indices n-jχ of typical magnetic fluids were evaluated for the sake of utilizing them as optical materials. Transmission and reflection spectra were measured in the wavelength range of 0.6-1.6 µm by using monochromators. Magnetic fluids were put into glass cells of 2.5-14-µm thickness for transmission measurement. Due to the absorption by magnetic fluids, the transmittance decreased notably with the increase of the sample thickness. The extinction coefficient χ was evaluated from the dependence of the transmittance on the sample thickness. χ was found to vary between 0.003 and 0.03 depending upon wavelength. The refractive index n was evaluated by fitting theoretical curves to the reflectances that were measured for various incident angles. n was found to vary between 1.6 and 1.7 depending slightly on wavelength. Since a magnetic fluid is a composite of ferrite particles and a solvent, the refractive index can be calculated by using the effective medium theory. The calculated value agreed well with the experimental value. Preliminary experiment of optical switching was also demonstrated by utilizing the mobility of a magnetic fluid.

  • An Improvement in the Standard Site Method for Accurate EMI Antenna Calibration

    Akira SUGIURA  Takao MORIKAWA  Kunimasa KOIKE  Katsushige HARIMA  

     
    PAPER-Electromagnetic Compatibility

      Vol:
    E78-B No:8
      Page(s):
    1229-1237

    Standard Site Method (SSM) is theoretically analyzed using matrix representations to examine its validity and develop an improved method. The analysis reveals that the SSM yields an antenna factor specifically related to the effective load impedance presented by the cable and associated devices which are disconnected from the antenna during the SSM site attenuation measurements. Therefore, an additional conversion is required to determine the desired antenna factor under actual load conditions. It is also concluded that the SSM is not applicable to antennas having height-dependent antenna factors. In addition, the SSM correction factors are found to be theoretically inappropriate. Uncertainty of the antenna factor obtained using the SSM is discussed and the required antenna separation distance is investigated. To improve the existing SSM, it is proposed that both transmitting and receiving antennas are placed at the same height during the site attenuation measurements. Experiments exhibit the superiority of the improved method.

  • Recent Progress of Electromagnetic Techniques in Hyperthermia Treatment

    Makoto KIKUCHI  

     
    INVITED PAPER

      Vol:
    E78-B No:6
      Page(s):
    799-808

    In the early stage of hyperthermia, a large number of engineering efforts have been done in the development or the improvement of the heating and temperature measuring techniques. However, they were not always satisfactory clinically. Thus, even in this moment, various engineering researches as well as the electromagnetic techniques for hyperthermia should be build up rapidly. This paper describes some of the highlights of developed or ongoing electromagnetic heating techniques in hyperthermia and identities a trend of emerging electromagnetic heating. Furthermore, the author emphasizes that few medical engineering efforts have been done in the boundary field between pure physics and clinics, and the proper way to develop the hyperthermia equipment is the best use of successes in the three essential regions: Physics, Biology and Clinics.

  • Uniform and Non-uniform Normalization of Vocal Tracts Measured by MRI Across Male, Female and Child Subjects

    Chang-Sheng YANG  Hideki KASUYA  

     
    PAPER

      Vol:
    E78-D No:6
      Page(s):
    732-737

    Three-dimensional vocal tract shapes of a male, a female and a child subjects are measured from magnetic resonance (MR) images during sustained phonation of Japanese vowels /a, i, u, e, o/. Non-uniform dimensional differences in the vocal tract shapes of the subjects are quantitatively measured. Vocal tract area functions of the female and child subjects are normalized to those of the male on the basis of non-uniform and uniform scalings of the vocal tract length and compared with each other. A comparison is also made between the formant frequencies computed from the area functions normalized by the two different scalings. It is suggested by the comparisons that non-uniformity in the vocal tract dimensions is not essential in the normalization of the five Japanese vowels.

  • Multi-Channel SQUID

    Hisashi KADO  Gen UEHARA  Hisanao OGATA  Hideo ITOZAKI  

     
    INVITED PAPER-SQUID sensor and multi-channel SQUID system

      Vol:
    E78-C No:5
      Page(s):
    511-518

    This paper describes a SQUID magnetometer and the measurement of small signals. It also describes the current state of SQUID technology developed in the SSL project.

  • MRI (Magnetic Resonance Imager)

    Yoshinori SUZUKI  

     
    INVITED PAPER-Applications of small-size high field superconducting magnet

      Vol:
    E78-C No:5
      Page(s):
    542-548

    MRI is a widely used diagnostic imaging modality because it has excellent diagnostic capabilities, is safe to use and generates images not affected by bone artifacts. Images are obtained by utilizing the phenomenon of Nuclear Magnetic Resonance (NMR) by which protons located in a static magnetic field absorb radiofrequency (RF) pulses with a specific frequency and release a part of the energy as a NMR signal. Potentially MRI has the ability to provide functional and metabolic information (such as flow, temperature, diffusion, neuron activity) in addition to morphological information. This paper describes the imaging principles and provides a general outline of some applications: flow imaging, metabolite imaging and temperature imaging.

  • High-Tc Superconducting Quantum Interference Device with Additional Positive Feedback

    Akira ADACHI  Ken'ichi OKAJIMA  Youichi TAKADA  Saburo TANAKA  Hideo ITOZAKI  Haruhisa TOYODA  Hisashi KADO  

     
    PAPER-SQUID sensor and multi-channel SQUID system

      Vol:
    E78-C No:5
      Page(s):
    519-525

    This study shows that using the direct offset integration technique (DOIT) and additional positive feedback (APF) in a high-Tc dc superconducting quantum interference device (SQUID) improves the effective flux-to-voltage transfer function and reduces the flux noise of a magnetometer, thus improving the magnetic field noise. The effective flux-to-voltage transfer function and the flux noise with APF were measured at different values of the positive feedback parameter βa, which depends on the resistance of the APF circuit. These quantities were also compared between conditions with and without APF. This investigation showed that a βa condition the most suitable for minimizing the flux noise of a magnetometer with APF exists and that it is βa=0.77. The effective flux-to-voltage transfer function with APF is about three times what it is without APF (93 µV/Φ0 vs. 32 µV/Φ0). The magnetic field noise of a magnetometer with APF is improved by a factor of about 3 (242 fT/Hz vs. 738 fT/Hz).

  • Development of Liquid Helium-Free Superconducting Magnet

    Junji SAKURABA  Mamoru ISHIHARA  Seiji YASUHARA  Kazunori JIKIHARA  Keiichi WATAZAWA  Tsuginori HASEBE  Chin Kung CHONG  Yutaka YAMADA  Kazuo WATANABE  

     
    INVITED PAPER-Applications of small-size high field superconducting magnet

      Vol:
    E78-C No:5
      Page(s):
    535-541

    Cryocooler cooled superconducting magnets using Bismuth based high-Tc current leads have been successfully demonstrated. The magnets mainly consisted of a superconducting coil, current leads and a radiation shield which are cooled by a two stage Gifford-McMahon cryocooler without using liquid helium. Our first liquid helium-free 4.6 T (Nb, Ti)3Sn superconducting magnet with a room temperature bore of 38 mm operated at 11 K has recorded a continuous operation at 3.7 T for 1,200 hours and total cooling time over 10,000 hours without trouble. As a next step, we constructed a (Nb, Ti)3Sn liquid helium-free superconducting magnet with a wider room temperature bore of 60 mm. The coil temperature reached 8.3 K in 37 hours after starting the cryocooler. The magnet generated 5.0 T at the center of the 60 mm room temperature bore at an operating current of 140 A. An operation at a field of 5 T was confirmed to be stable even if the cryocooler has been stopped for 4 minutes. These results show that the liquid helium-free superconducting magnets can provide an excellent performance for a new application of the superconducting magnet.

  • Heating Phenomena in the Vibrating Superconducting Magnet on Maglev

    Eiji SUZUKI  

     
    INVITED PAPER-Applications of small-size high field superconducting magnet

      Vol:
    E78-C No:5
      Page(s):
    549-556

    The superconducting magnet on a maglev vehicle vibrate and heats up inside under the influence of various disturbances in running. We have investigated the characteristics of heating in the superconducting magnet vibrating under the electro-magnetic disturbance from the ground coils. This magnetic disturbance has a frequency component ranging widely from 0 Hz to several hundred Hz which is proportional to the speed of the maglev vehicle. It was revealed that an extreme increase of heat load on the inner vessel of the energized magnet occurred at a particular frequency and it surpassed the capacity of the refrigerator installed in the tank of the superconducting magnet. As a result of the investigation, we could identify broadly three factors of heating, and now we have good prospects of largely suppressing the heating by reducing the disturbance through the folded arrangement of the ground coils and a structural improvement of the magnet.

  • An Experimental Study on Subjective Evaluation of TV Picture Degradation by Electromagnetic Noise--Opinion Tests on Still and Motion Pictures--

    Motoshi TANAKA  Hiroshi INOUE  Tasuku TAKAGI  

     
    PAPER

      Vol:
    E78-B No:2
      Page(s):
    168-172

    The effects of Gaussian electromagnetic noise and non-Gaussian one on TV picture degradation are studied by using a composite noise generator which can control noise parameters. Three kinds of still pictures and four kinds of motion pictures are tested, and the picture degradation is subjectively evaluated with five-grade impairment scale. The tendency of the picture degradation against the every picture is almost the same. But MOS (Mean Opinion Score) between still picture and motion picture degradation is different in some measure when the power of burst noise is small.

  • Roles and Problems of LISN in Noise Measurement

    Shuichi NITTA  

     
    INVITED PAPER

      Vol:
    E78-B No:2
      Page(s):
    109-119

    This paper describes, based on generation mechanism of conductive noise, that the real conductive noise on AC-mains can't be measured by LISN and 50 Ω-input impedance instrument specified by regulations such as CISPR. Second, it is pointed out that one of the causes of poor reproducibility in radiated emission measurement is the difference among line impedances of AC-mains. Finally, it is insisted that the apparatus such as LISN is necessary for stable measurement of radiated emission, and what improvement on LISN characteristics for higher frequency range should be done is introduced.

  • Electromagnetic Shielding Effectiveness: Effects Due to Gap Size and Angle of Cut

    Behzad D. MOTTAHED  Souran MANOOCHEHRI  

     
    PAPER

      Vol:
    E78-B No:2
      Page(s):
    207-211

    Effects of various joint configurations and gap sizes on the electromagnetic shielding effectiveness (SE) are evaluated to provide guidelines for best design of joints in order to increase the value of SE. Four different joint geometries are presented. A sharp decrease on SE with larger gap size for simple joints is observed. Addition of bends in the joint geometry has strong positive effect on the value of the SE. Increasing the angle of cut, which increases the effective length of the joint were also demonstrated to have increasing effect on the shielding performance.

  • Electromagnetic Environments Generated by Power Transmission System

    Seietsu TOMITA  

     
    INVITED PAPER

      Vol:
    E78-B No:2
      Page(s):
    120-126

    Electromagnetic environments generated by power transmission system, possibilities of the interference and its mitigation method was introduced. In the frequency region below 10kHz, concern for DC and AC electric and magnetic field are described. In the frequency range above 10kHz, concern for discharges on power apparatus, electromagnetic emvironments generated by carrier system and fault locating system and passive interference are described. Electromagnetic environment caused by load equipments, that is harmonics, and undesirable electromagnetic emission from power converting units are described finally.

  • Approximation of Surface-SAR in a Realistic Head Model for Microwave Exposure Using External Magnetic Near-Field

    Osamu FUJIWARA  Michihiko NOMURA  

     
    PAPER

      Vol:
    E78-B No:2
      Page(s):
    140-144

    A method is described for approximately estimating the surface specific-absorption-rate (SAR) in an anatomically realistic model of the human head for microwave exposure using the external magnetic near-field. The finite-difference time-domain (FD-TD) technique is used to compute the electromagnetic fields in the head model for 750-MHz and 1.5-GHz far-field exposures with the 1991 ANSI specified safety level. The spatial pattern tracking between the one-gram averaged surface-SAR and external magnetic near-field is demonstrated on the horizontal cross sectional perimeter of the head model. The regression coefficients between them are also obtained on the fifty-five horizontal cross sectional perimeters, which could give an approximate value of the surface-SAR in an acutual head, if the external magnetic near-field would be measured. This is validated by the theoretical results in a semi-infinite homogeneous flat model for normal incidence microwave exposure.

  • Radiated Emission Estimation of a Metallic Enclosure Model Source by Inverse-Forward Analysis

    Shose HAYASHI  Koichiro MASUDA  Ken-ichi HATAKEYAMA  

     
    PAPER

      Vol:
    E78-B No:2
      Page(s):
    173-180

    For estimating the radiated emission from a metallic enclosure, the authors have developed a numerical computational method which applied inverse analysis. A metallic enclosure containing a loop antenna was set up to be a model source for the numerical analysis. Magnetic fields around the enclosure were measured by measurement systems fabricated in the authors' laboratory. Using the measured magnetic fields, current distributions on the enclosure surface were determined by means of an inverse analysis utilizing the least squares method. From this surface current distribution, the electromagnetic field distributions were estimated by forward analysis on a cylindrical surface 3.0m in radius. The amount of the error in the estimated fields distribution was also discussed.

  • Evaluation of Antenna Factor of Biconical Antennas for EMC Measurements

    Koichi GYODA  Yukio YAMANAKA  Takashi SHINOZUKA  Akira SUGIURA  

     
    PAPER

      Vol:
    E78-B No:2
      Page(s):
    268-272

    Broadband antennas such as biconical antennas and log-periodic dipole antennas are generally used in automatic EMC measurements. However, these broadband antennas have not been used for accurate measurement because accurate specifications for them are lacking. Therefore, more accurate analysis is urgently required by the CISPR (International Special Committee on Radio Interference), to establish the specifications for broadband antennas for EMC measurements. In this paper, the AF of biconical antennas is calculated by using Moment Methods. The frequency characteristics and antenna height dependency of AF are presented. AF is also measured and compared to the data obtained by the calculations. Good agreement between the calculations and measurements is achieved, indicating the usefulness of our computation method. In addition, the effect of antenna separation distance and transmitting antenna height on AF is investigated. The calculated AF deviation from the reference value is nearly 0dB except for certain antenna arrangements. In these antenna arrangements, the field becomes null at the receiving antenna and widely varies in magnitude and phase around the null points. Therefore, the antenna is immersed in a non-uniform field, while the AF is defined on the assumption of a uniform field. Consequently, the erroneous AF will be derived from measurements around these null points and it will be greatly different from that obtained at other antenna heights. Thus, it is better to avoid these conditions during actual measurements. The effect of the ground plane on AF is also evaluated. AF is shown to be seriously affected by the ground plane especially at frequencies around 90MHz. It should be noted that AF deviation has crests corresponding to the null field at 300MHz. The obtained data will be useful in establishing specifications of biconical antennas for EMC measurements.

  • Measurements on Low Frequency Phase and Amplitude Fluctuations and Its Application to Reduce the Noise in Bipolar Transistor Circuits

    Keiji TAKAGI  

     
    LETTER

      Vol:
    E78-B No:2
      Page(s):
    279-280

    A system for measuring the low frequency amplitude and phase noises was set-up, with employing a phase sensitive detector and phase-shifter. It is noted that both noises were partly correlated. The phase noise was explained by the transit time fluctuation due to the fluctuating diffusion coefficient. The amplitude noise reduction was demonstrated by applying the inverted output of the phase noise to the amplitude noise.

  • Prediction of Peak Frequencies on Electromagnetic Emission from a Signal Line on a Printed Circuit Board

    Takuya MIYASHITA  Osami WADA  Ryuji KOGA  Hiroya SANO  

     
    PAPER

      Vol:
    E78-B No:2
      Page(s):
    181-187

    Concerned is a spectral profile of electromagnetic (EM) emission from a signal line on a high-speed digital circuit. The authors have proposed and examined an a priori method to predict the peak frequencies on spectral profile of EM emission from printed circuit boards (PCBs). Profile of an EM spectrum is determined by the resonance of digital circuits. It is the purpose of this paper to investigate the parameters that determine the spectral profile of EM emission from a signal line on a PCS. In this paper, measurements and calculations of EM spectra were carried out for different load capacitances. EM emissions were measured with a small loop antenna at a 50mm from the surface of the PCB. Measured EM spectra had two peaks. Calculated EM spectra, which was based on transient current given by the analog simulator SPICE, had two peaks too. Results of calculations of EM spectra for different internal capacitances of an IC tell that lower peak frequency is determined by the resonance frequency of the resonant loop which is composed of an IC package and a decoupling capacitor. Comparison with measured EM spectra and calculated EM spectra for different load resistances tell that sharpness of the other peak depends on Q factor of a resonant loop which includes a signal line. Therefore the peak frequencies of EM emission spectrum can be predicted as two resonance frequencies of two resonant circuits.

  • FDTD Analysis of Unit-Radiator for a Circularly Polarized Printed Array Antenna Composed of Strips and Slots

    Motoyuki NAITO  Shin-ichiro MATSUZAWA  Koichi ITO  

     
    PAPER-Antennas and Propagation

      Vol:
    E77-B No:12
      Page(s):
    1621-1627

    The validity of numerical design scheme of CP-PASS (Circularly Polarized Printed Array antenna composed of Strips and Slots) is considered. The strip element of CP-PASS is composed of a strip dipole and a window which increases the frequency bandwidth of the strip element. With the window, however, analysis of the antenna becomes difficult if a simple analytical model is used. The previous design procedure requierd an experimental procedure. By using modern computers, the FDTD (finite-difference time-domain) method becomes powerful tool for the analysis of 3D-structured antennas. In this paper, numerical results of the FDTD analysis for CP-PASS is compared with results from experiments. The characteristics of the unit-radiator of CP-PASS are demonstrated numerically. This paper shows that CP-PASS can be designed numerically and a new path has opened in the study of CP-PASS.