[Keyword] discharge(99hit)

81-99hit(99hit)

  • A Fundamental Study on Effect of Contact Condition for Electromagnetic Noise at Copper-Carbon Electrodes

    Yasuo EBARA  Toshiaki KOIZUMI  Hideaki SONE  Yoshiaki NEMOTO  

     
    PAPER

      Vol:
    E82-C No:1
      Page(s):
    49-54

    The authors observed the correlation between electromagnetic noise and trace of discharge on surface for various surface areas of Cu in opening copper (Cu)-carbon (C) electrodes. In the case of Cu (anode)-C (cathode), the duration of sporadic burst noise generated by discharge becomes longer when Cu surface area is increased, and trace of discharge (melting area) distribute widely on electrodes. Also the forms of the burst noise in the start of arc are classified, and the traces of discharge correspond to each forms. The forms of the burst noise depend on the pattern which the trace of discharge are formed. As these results, the authors showed the correlation between form of burst noise and trace of discharge on electrode surface.

  • Estimation for the Spot Size of Short Gap Discharge in Near One Atmospheric Pressure

    Kagehiro ITOYAMA  Takeshi YANOBE  

     
    PAPER

      Vol:
    E82-C No:1
      Page(s):
    55-59

    This paper proposed the method as an estimation on the size of discharge spots through observation on traces after the discharge arose in circumstances gases mixed hydrocarbon gas. Namely, the circular carbonaceous deposit and the carbonaceous heap are observed on cathode and anode surface, respectively, after the short gap discharge arises in N2+NO+CH4 gases. The current density, which is the normal conversion current density, is calculated from the size of the trace of discharge and its value is about 1.010-9 A/(cm2 Pa2) in case that the concentration of CH4 is 0.6%. The value is about 1/5 of values that are reported in the former articles and is reasonable one.

  • Arc and Contact Resistance Characteristics of Ag and Pd Contacts in Dielectric Liquids

    Toshiro HAYAKAWA  Koichiro SAWA  

     
    PAPER

      Vol:
    E81-C No:3
      Page(s):
    392-398

    Arc and contact resistance characteristics of Ag and Pd contacts were determined in several kinds of dielectric liquids, such as distilled water, methanol and n-hexane, under the inductive load condition. The experimental results showed that arc discharge types are dependent on dielectric liquids. A steady arc develops in air under this test condition. However, it was found that not the steady arc but the showering arc occurs in distilled water and methanol at a low load current. It was demonstrated that this phenomenon is caused by the high capacitance generated by the ambient dielectric liquid. Also, in almost all cases, the contact resistance behavior in dielectric liquids is satisfactory because metal spots remain on the contact surface. However, in n-hexane, the contact resistance tends to deteriorate, particularly for the Ag contact, with increasing load current. It seems that the deterioration of contact resistance is caused by carbon included in n-hexane.

  • A Proposal on Contact Surface Model of Electromagnetic Relays Based on the Change in Showering Arc Waveforms with the Number of Contact Operations

    Kiyotomi MIYAJIMA  Shuichi NITTA  Atsuo MUTOH  

     
    PAPER

      Vol:
    E81-C No:3
      Page(s):
    399-407

    The showering arc waveforms generated when contact is being separate have poor reproducibility whose causes are not sufficiently clear. This paper describes that the contact surface conditions which change with the number of contact operations are deeply related to the showering arc waveforms. First, it is experimentally shown that the contacts' surface roughness increases with the number of contact operations, and the growth model of contact surface roughness is proposed based on the change of contact resistance for the number of contact operations. Second, the growth model of molten metal bridge is proposed based on the fact that the showering arc waveforms change with the number of contact operations and the evaluation indexes of showering arc are proposed.

  • Influence of Non-uniform Electric Field on the Firing Voltage of Surface Discharge AC-PDPs

    Mitsuyoshi MAKINO  Toshihiro YOSHIOKA  Takeshi SAITO  

     
    PAPER

      Vol:
    E80-C No:8
      Page(s):
    1086-1090

    The cell structure of surface discharge ACPDPs with a long gap between the sustaining electrodes achieves high luminous efficiency. However, the long gap cell structure causes high firing voltage and thus makes driving more difficult than with the conventional gap cell structure. The rise in firing voltage in the long gap cell structure could not be explained by Paschen's scaling law. We derived a new governing equation for firing voltage, involving the influence of a non-uniform electric field, to investigate this deviation from Paschen's law. From the calculated results we found that changing the gap length corresponds to the change in the degree of distortion of the electric field between the sustaining electrodes.

  • Induced Noise from Arc Discharge and Its Simulation

    Hiroshi INOUE  

     
    INVITED PAPER

      Vol:
    E79-B No:4
      Page(s):
    462-467

    Induced noises from breaking contact arc discharge and sliding contact discharge of dc motor are measured by pick up coil and current probe. Statistical properties, amplitude distribution probability (APD), of induced noise waveform are analyzed by simple method using intermediate frequency of spectrum analyzer. It is shown that APD characteristics can be used to estimate statistical characteristics and peak value of induced noise. Simulation model of the noise made by the combination of Gaussian noise is mentioned. The model called the composite noise generator (CNG) can be good fit to the real characteristics of both noises from breaking arc and dc motor. Applications of the CNG for noise filter using toroidal coil shows that the CNG is useful to realize the test of noise suppression characteristics. What parameters of the CNG should be considered is described for further applications.

  • Evaluation of Charge Transition in a Small Gap Discharge

    Shinobu ISHIGAMI  Takashi IWASAKI  

     
    PAPER

      Vol:
    E79-B No:4
      Page(s):
    474-482

    The charge neutralized at a small gap discharge has been evaluated from measured electromagnetic fields by two methods. The small gap discharges simulate ESD events. The evaluated charge decreases rapidly as a step shape immediately in a moment of the discharge. The accumulated static charge and the risetime of the neutralization step increase with the gap length. When the gap length is 0.1mm, risetime and the initial static charge are about 0.3ns and 5.6nC, respectively.

  • Electromagnetic Emissions from Atmospheric Pressure Gas Discharges

    Jen-Shih CHANG  

     
    INVITED PAPER

      Vol:
    E79-B No:4
      Page(s):
    447-456

    Over the past few years, many industrial processes have switched to electrical processes from conventional fossil fuel as a primary energy source, since electricity can be transmitted more economically than the transport of fossil fuels, as well as less pollution problems and labour- and spacesaving nature. For the environmental protections, ozone generation for water treatments, and decomposition of pollution gases such as SOx, NOx, COx, etc., by high pressure gas discharge processes become an important research subject. However, due to the early stage of development, the EMC problem is not yet well considered. In this review, we try to address the EMC problem in the various atmospheric pressure gas discharge processing techniques and identify future needs of research.

  • Electromagnetic Radiation Noise from Surface Gas Discharges-Mechanisms of Propagation, Coupling and Formation

    Keiichi UCHIMURA  Shuichi NITTA  Jen-Shih CHANG  

     
    PAPER

      Vol:
    E79-B No:4
      Page(s):
    490-496

    Surface discharge is widely used for industrial ozonizers and toxic gas treatments, and is noise source. In this paper, an experimental investigation from the point of view of electromagnetic compatibility (EMC) has been conducted to evaluate the noise characteristics of surface discharge combustion flue gas cleaning systems. Mechanisms of propagation, coupling and formation are proposed based on the experimental observations.

  • Arc Discharge at Electrical Contacts

    Koichiro SAWA  Zhuan-Ke CHEN  

     
    INVITED PAPER

      Vol:
    E79-B No:4
      Page(s):
    439-446

    Arc discharge at switching contacts is one of the key phenomena, because it strongly affects material wear/transfer, contact resistance and electromagnetic interference (EMI). The arc discharge is classified into various types from the viewpoint of its sustaining mechanism and voltage waveform. They are mainly steady arc, showering arc and initial arc. Furthermore, a steady arc consists of two stages named metallic phase arc and gaseous phase arc. In the metallic, phase arc, metal ious from the electrodes mainly sustain the arc. On the other hand, gas ions from the surrounding atmosphere play an important role in the gaseous phase. Each phase arc has different influence on contact performance and EMI. The purpose of this paper is to review the arc discharges at light duty electrical contacts, and to survey the effects of arc discharges on material transfer and EMI.

  • Vertical Magnetoresistive/Inductive Head

    Takuji SHIBATA  Munekatsu FUKUYAMA  Norio SAITO  Yoshitaka WADA  Yutaka SODA  

     
    INVITED PAPER

      Vol:
    E78-C No:11
      Page(s):
    1493-1498

    A vertical magnetoresistive (MR)/inductive head using the current bias technique has been developed for high-density magnetic recording. In this head, the sense current is orthogonal to the air-bearing surface (ABS). The area exposed at the ABS of the MR element is beneath the front lead, and the active area of the sensor is positioned behind that area. The MR element is composed of two permalloy films separated by a thin nonmagnetic material. The easy axis of the films is oriented parallel to the ABS and the films are magnetostatically coupled. The magnetic field created by the sense current is applied in the direction of the easy axis and the MR element is stabilized. In this head structure, no MR-element-stabilizing layer, such as an antiferromagnetic film or a hard magnetic film, is needed. Since the permalloy film beneath the front lead acts as a front flux guide, the signal flux propagates in the sensing area of the MR element behind the ABS. The new vertical MR head has the same electrical performance characteristics as the conventional horizontal MR head. The offtrack signal profile is symmetric against the track center because the magnetization of the two permalloy films rotates symmetrically in the signal-flux direction. The output signal level of this head is independent of the read trackwidth, which favors a narrow trackwidth. The exposed portion at the ABS is only connected to the common lead and is at ground potential. In this design, electrostatic breakdown does not occur and no corrosion is observed. Tests have shown that as the flying height is reduced, the error rate is reduced and noise does not increase. This head structure appears suitable for the near-contact recording of the near future.

  • A Method for Reducing Power Consumption of CMOS Logic Based on Signal Transition Probability

    Kunihiro ASADA  Junichi AKITA  

     
    PAPER-DA/Architecture

      Vol:
    E78-C No:4
      Page(s):
    436-440

    Some CMOS gates are topologically asymmetric in inputs, even though they are logically symmetric. It implies a possibility to reduce power consumption by optimizing signal assignment to the inputs. In this study we theoretically derive power consumption of 2-input NAND gate based on transition probability of input signals, with taking into account charging current due to an internal node. We also propose a signal assignment method to input terminals for reducing power consumption reduction by extending our method for large circuits, and demonstrate the effect of power consumption reduction by the present method.

  • Electromagnetic Environments Generated by Power Transmission System

    Seietsu TOMITA  

     
    INVITED PAPER

      Vol:
    E78-B No:2
      Page(s):
    120-126

    Electromagnetic environments generated by power transmission system, possibilities of the interference and its mitigation method was introduced. In the frequency region below 10kHz, concern for DC and AC electric and magnetic field are described. In the frequency range above 10kHz, concern for discharges on power apparatus, electromagnetic emvironments generated by carrier system and fault locating system and passive interference are described. Electromagnetic environment caused by load equipments, that is harmonics, and undesirable electromagnetic emission from power converting units are described finally.

  • Measurements of Fast Transient Fields in the Vicinity of Short Gap Discharges

    Shinobu ISHIGAMI  Ryoichi GOKITA  Yoshifumi NISHIYAMA  Ichiro YOKOSHIMA  Takashi IWASAKI  

     
    PAPER

      Vol:
    E78-B No:2
      Page(s):
    199-206

    The wave forms of electric and magnetic fields radiated by short gap discharges are measured to analyze electrostatic discharge (ESD) events in the near-field zone with the monopole antennas, the loop antenna and the 5.5GHz bandwidth waveform digitizer. The antenna outputs are corrected by the measured characteristics of the antennas. The relations between the measured electric field and the discharge currents are discussed.

  • Simultaneous Measurements of Two Wavelength Spectra for Ag Break Arc

    Kiyoshi YOSHIDA  Atsuo TAKAHASHI  

     
    PAPER-Arcing Discharge and Contact Characteristics

      Vol:
    E77-C No:10
      Page(s):
    1640-1646

    The authors have studied mechanism of transition from metallic phase to gaseous phase in contact break arc. For further elucidation of the mechanism, we have carried out spectroscopic measurement. The spectrum measurement system which had high time resolution was composed using two monochromators and a bifurcated image fiber, which had one input port and two output ports. The input port received the arc light, and the two monochromators received the arc light from the two output ports, respectively. The spectral sensitivity of the two monochromators was corrected with a standard lamp. We have measured simultaneously two spectra of break arc for Ag in laboratory air, under the condition where source voltage E=48 V, load inductance L=2.3 mH, and closed contact current I0=6 A. As a result, the time-varying tendency of spectrum intensity is similar for the same element, even if the wavelength is different. And from the comparison of time average spectrum intensity, it is clarified that average intensity for gas spectrum does not attain to 10% of that for metallic atomic spectrum (Ag I, 520.91 nm). In addition, the decrease point of Ag II (ion) spectrum has been found to correspond with the peak of Ag I (atom) spectrum.

  • An Experimental Study on Material Transfer and Arc Erosion Characteristic of Ag Contacts under Switching Lower Current

    Hiroaki MIZUKOSHI  Koichiro SAWA  Makoto HASEGAWA  Kae NIIZUMA  

     
    PAPER-Arcing Discharge and Contact Characteristics

      Vol:
    E77-C No:10
      Page(s):
    1655-1661

    Arc discharge between electrodes of relays and switches often causes contact surface damage through material transfer and arc erosion. Especially, material transfer sometimes occurs and brings serious failure even under lower load that is quite smaller than the minimum arc current value of contact material. In this paper, contact surface configuration, material transfer, and arc erosion characteristics of Ag and AgPd 60 contacts were experimentally studied after 0.5 or 1 million switching operations at various load levels. The followings can be made clear. Firstly, it was confirmed that the arcs and material transfer occurred even under such current that was lower than the minimum arc current. Therefore, the definition of the arc occurrence boundary current was newly determined. Secondly, the relation between load conditions (current and power supply voltage) and contact surface configuration (craters and pips) caused by material transfer was studied. The arc erosion behaviors of tested samples could be classified into two types: material transfer type and wear-out type. As one of the primary factors of transition from the former type to the latter one, contact activation was considered. The influences of load conditions and organic gas emitted from relay structure on arc characteristics was experimentally examined. The results indicated that load current greatly influenced the amount of material transfer and that power supply voltage affected the occurrence of the wear-out type significantly. The activation behavior of the contact surface could be found through observing the bridge voltage waveform.

  • Recent Development of Testing System for Arcing Contacts

    Hideaki SONE  Tasuku TAKAGI  

     
    INVITED PAPER

      Vol:
    E77-C No:10
      Page(s):
    1545-1552

    Reliability of an electric contact can be defined by two parameters, contact resistance and wear, and the parameters of contacts operated in arcing condition are governed by the arc discharge. Thus the measurement on the relationship between the parameters and arc phenomena is necessary to improve the contact performance. The parameters for arcing electric contacts and problems were reviewed, and new concept for electric contact testing systems was proposed. Measurement with such an advanced system should be concurrent parallel measurement, quantitative measurement of degradation, systematic measurement, and analysis of arc discharge phenomena. Some examples of advanced measurement systems and new data obtained with such systems were described. Systematic results on relationships between condition and performance parameters were obtained by systematic measurement with systematically settled conditions, such as opening speed or material condition. A measurement method for the metallic phase arc duration was developed by the authors, and role of the metallic phase arc on contact performance parameters was found from interpretation of obtained data. The real-time surface profile measurement of an operating contact and the optical transient spectrum analyser for arc light radiated from breaking contact were also described.

  • Analysis of Transient Electromagnetic Fields Radiated by Electrostatic Discharges

    Osamu FUJIWARA  Norio ANDOH  

     
    LETTER-Electromagnetic Compatibility

      Vol:
    E76-B No:11
      Page(s):
    1478-1480

    For analyzing the transient electromagnetic fields caused by electrostatic discharge (ESD), a new ESD model is presented here. Numerical calculation is also given to explain the distinctive phenomenon being well-recognized in the ESD event.

  • 1/5 Power Law in PN-Junction Failure Mechanism Caused by Electrical-Over-Stress

    Yutaka TAJIMA  Kunihiro ASADA  Takuo SUGANO  

     
    PAPER

      Vol:
    E75-C No:2
      Page(s):
    207-215

    We have developed a new model to analyze the thermal failure mechanism due to electrical-over-stress (EOS) for two-dimensional planar pn-junction structures where the failure power is proportional to about 1/5 power of the failure time. We adopted a pseudo two-dimensional numerical simulation method where a pn-junction diode is divided into small elements and represented by a circuit network composed of many minute resistors and diodes. The failure mechanism studied by Wunsch and Bell, that is one of many studies for one-dimensional pn-diodes, is not valid for the case of two-dimensional pn-junction, such as a planar type junction. On the contrary, the failure mechanism was found to be much correlative with the junction structure, especially the impurity concentration in the substrate in the two-dimensional case. When the impurity concentration in the substrate is high enough (e.g. Nsub1017[cm-3]), the breakdown occurs at the whole junction. The heat transfer is one-dimensional and the failure power is proportional to about 1/2 power of the failure time, which is well known results reported by many researchers: e.g. Wunsch &Bell. On the other hand, when the impurity concentration in the substrate is low enough (e.g. Nsub1016[cm-3]), the breakdown occurs locally at the junction edge. The heat transfer is two-dimensional and the failure power is in proportion to about 1/5 power of the failure time.

81-99hit(99hit)